目前分類:Data centre (558)
- Feb 09 Fri 2018 09:43
機房建置設備的設置需求
- Feb 09 Fri 2018 09:34
Key points for location of data center migrating machine room
Data center migration
1. The average load-bearing of the machine room is not less than 1000KG/ flat, and the UPS battery should be designed according to the actual equipment.
- Feb 08 Thu 2018 09:59
The most intuitive data center fire system
Fire system is an essential guarantee for the machine room. The fire protection of the machine room must adopt the automatic fire extinguishing device without corrosion. The fire extinguishing device has reliable fire extinguishing performance, no damage to electronic equipment, and the installation of dark pipe cloth does not affect the overall effect of the machine room.
- Feb 08 Thu 2018 09:46
機房建置數據中心爲何採用LED燈具照明
- Feb 08 Thu 2018 09:34
How do data center migration avoid dust pollution?
The data center migration is not very good because of the large number of servers and all kinds of devices. Does the installation of air ionization equipment in the data center help to improve this situation? Will there be a lot of maintenance trouble and a big increase in cost?
- Feb 07 Wed 2018 09:59
How to reduce the energy cost of the Cooling system
Cooling system,In improving the energy efficiency of the data center, the IT load itself is the most important part of the consideration. The next is the load of the refrigeration system, which is the second major energy consumption part of the data center. Therefore, great efforts have been made to ensure the efficient operation of the refrigeration system.
- Feb 07 Wed 2018 09:48
機房建置製冷系統如何降低能源成本
- Feb 07 Wed 2018 09:30
Machine relocation in data center migration
Data center migration as a IT operation and maintenance personnel, in addition to IT equipment for routine inspection, fault maintenance, log review and security vulnerabilities protection, but also deal with the relocation of data center machines.
- Feb 06 Tue 2018 10:03
The importance of the UPS system to the data center
UPS system, for the data center, in the operation of the power system, the inevitable failure. Although the probability of the failure is very small and the duration is not long, the consequences are often very serious. When a power system fails, the state of operation will undergo a dramatic change. So the application of UPS system is particularly important for the uninterrupted operation of the power system of the machine room. The daily inspection and maintenance of UPS system is also the most important.
- Feb 06 Tue 2018 09:53
光伏電站數據中心機房建置系統架構
- Feb 06 Tue 2018 09:34
Energy saving method of data center migration
The data center migration, energy efficiency measurement standard is the energy utilization ratio of the sacristy (PUI), a low ratio shows better utilization rate, 1 is the ideal target of energy efficiency. 2, the common value of the ratio implies that the consumption of 2 watts of energy in the data center has dropped to 1 watts when the data center is tested. The loss is that energy is transformed into heat and then needs energy to dispel the heat through the traditional data center refrigeration system.
- Feb 05 Mon 2018 10:14
CRAC: humidity control device in air conditioning
The air conditioner in the CRAC room has the function of dehumidification, which is realized by the humidity controller. There are many kinds of humidity controller in the air conditioner, such as humidity controller of dry and wet ball, hair, moisture regulator of nylon film, lithium chloride humidity regulator and so on.
- Feb 05 Mon 2018 09:58
機房建置:數據中心擴張的新業務模式
- Feb 05 Mon 2018 09:44
Data centers migration safe haven: Northern Europe
Data center migration. It is reported that some countries in northern Europe (Denmark, Finland, Iceland, Norway and Sweden) have invested more than 3 billion euros in data centers in the next three years.
- Feb 03 Sat 2018 10:32
FM200: how to do the fire system in the data center machine room
The FM200 fire fighting system aims at the fire situation caused by fire sources outside the computer room. When designing data centers, we should consider the heat insulation performance of walls and ceilings, and use fireproof materials. When a fire is produced from other places, to a certain extent, it can help to reduce or delay the damage of the fire.
- Feb 03 Sat 2018 10:19
機房建置智能直冷優化技術
- Feb 03 Sat 2018 10:12
Data center migration, location is still important
Data center migration,location plays a vital role in the decision-making process of each company. The enterprise is investing in where to choose, where to build it, where the employees come from, and where and how to manage the data.
- Feb 02 Fri 2018 10:20
數據中心內部環境清掃三原則
數據中心裏有大量電子設備,這些設備並非工業級(工業級的有專門寬溫設計,抗粉塵設計,這類設備往往應用於特殊場合,爲了能夠在這樣惡劣環境中正常工作,這類設備往往會造價很高,很難在數據中心裏大面積推廣)的設計,對運行工作環境有一定要求,尤其是清潔度。如果數據中心裏溼度過於乾燥或者潮溼,各種霧霾、粉塵、有害氣體等充斥在環境中,將對運行的設備造成嚴重傷害,大大縮短設備的使用壽命。所以,保持數據中心內的環境清潔十分必要。不過,數據中心畢竟和普通的場所不同,簡單的打掃衛生難以達到效果,需要制定一套完善的清理衛生制度,並有條不紊地去執行,否則做不好反而帶來更大的損害。本文就來講一講數據中心裏的衛生清掃問題。
- Feb 02 Fri 2018 10:08
機房建置網站空間服務器的正確選擇方法
- Feb 02 Fri 2018 09:43
Construction of data center migration infrastructure
The current data center migration, industrial application of all kinds of big data technology and the emergence of the growth of the amount of data showing a blowout, and users of the data center business availability requirements are also put forward new demands to change.In this context, the data center infrastructure is faced with new challenges and opportunities, modularization, intelligence, rapid expansion, flexibility, and environmental protection.